- First Alert Smoke Detector Beeping
- First Alert Smoke And Co Detector User Manual Instructions
- First Alert Smoke And Carbon Monoxide Alarm Manual
- First Alert Smoke And Carbon Monoxide Alarm Owners Manual
5
IF THE CO ALARM SOUNDS
Actuation of your CO Alarm indicates the presence of carbon
monoxide (CO) which can kill you. In other words, when your CO
Alarm sounds, you must not ignore it!
Dec 14, 2017 The First Alert PC900 Battery-Operated Combination Photoelectric Smoke and Carbon Monoxide Alarm packs premium detection capabilities into a sleek, compact design. For those who want a reliable detection system without hiring an electrician or worrying about hardwiring, this battery-operated smoke and carbon monoxide detector is an ideal solution. The First Alert SCO7CN Battery-Operated Combination Smoke and Carbon Monoxide Alarm with Voice and Location delivers both smoke and carbon monoxide detection in a single unit. Equipped with a photoelectric smoke sensor and an electrochemical CO sensor, it accurately detects smoke produced by smoldering fires and carbon monoxide leaks from. First Alert® is Canada’s most trusted brand in home safety and an industry leader in offering families’ peace of mind. Get conveniently connected with your Onelink® Smoke + Carbon Monoxide alarm with WiFi® connectivity and help keep your.
IF THE CO ALARM SIGNAL SOUNDS:
1. Operate the Test/Silence button.
2. Call your emergency services, fire department or 911. Write down the
number of your local emergency service here:
____________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or
window. Do a head count to check that all persons are accounted
for. Do not re-enter the premises, or move away from the open door
or window until the emergency services responder has arrived, the
premises have been aired out, and your CO Alarm remains in its
normal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a
24-hour period, repeat steps 1-3 and call a qualified appliance tech-
nician to investigate for sources of CO from fuel-burning equipment
and appliances, and inspect for proper operation of this equipment.
If problems are identified during this inspection have the equipment
serviced immediately. Note any combustion equipment not inspected
by the technician, and consult the manufacturers’ instructions, or
contact the manufacturers directly, for more information about CO
safety and this equipment. Make sure that motor vehicles are not,
and have not, been operating in an attached garage or adjacent
to the residence. Write down the number of a qualified appliance
technician here:
____________________________________________________________
“ALARM-MOVE TO FRESH AIR”
If you hear the CO alarm horn and the CO red light is flashing,
move everyone to a source of fresh air.
DO NOT remove the batteries!
IF YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST–IDENTIFY THE TYPE OF
ALARM SIGNAL
Refer to previous section “What You Will See and Hear With This
Alarm”.
AFTER AN ALARM
After the emergency responders arrive, the premises aired out, and
your CO Alarm remains in its normal condition, you can check what
the highest carbon monoxide level sensed was:
Action:
1. Press & Hold Test Button
Alarm Will Say:
“Highest carbon monoxide level
was ___ ppm. Please see manual.”
“To clear highest carbon monoxide
level, press and hold test button
now.”
2. Press & Hold Test Button, if you
would like to clear the highest
level sensed.
If you would like to keep the
highest level in memory, do not
press anything.
“Highest carbon monoxide level
cleared.”
Alarm will say nothing.
IF THE SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
•
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
•
Never remove the batteries from a battery operated Smoke/CO
Alarm to stop an unwanted alarm (caused by cooking smoke,
etc.). Removing batteries disables the alarm so it cannot sense
smoke, and removes your protection. Instead open a window
or fan the smoke away from the unit. The alarm will reset auto-
matically.
•
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
• Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to get
dressed or collect anything.
• Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
• Meet at your planned meeting place outside your home, and
do a head count to make sure everybody got out safely.
• Call the Fire Department as soon as possible from outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home
First Alert Smoke Detector Beeping
safer.
Alarms have various limitations. See 'General Limitations of
Smoke/CO Alarms' for details.
USING THE SILENCE FEATURES
Never remove the batteries to quiet an unwanted alarm. Removing
the batteries disables the alarm and removes your protection.
The Silence Feature is intended to temporarily silence the horn while
you identify and correct the problem. Do not use the Silence Feature in
emergency situations. It will not correct a CO problem or extinguish a
fire.
The Silence Feature can temporarily quiet an unwanted alarm for several
minutes. You can silence this Smoke/CO Alarm by pressing the
Test/Silence button on the alarm cover for at least 3-5 seconds.
After the Test/Silence button is released, the Red LED blinks during the
silence mode.
When the Smoke Alarm
is Silenced
When the CO Alarm
is Silenced
The Smoke Alarm will remain
silent for up to 15 minutes, then
return to normal operation.
If the smoke has not cleared–or
continues to increase–the device
will go back into alarm.
First Alert Smoke And Co Detector User Manual Instructions
The CO Alarm will remain silent
for up to 4 minutes.
After 4 minutes, if CO levels
remain potentially dangerous the
horn will start sounding again.
» Locked Battery Drawer
» Electrochemical Carbon Monoxide Sensor - the most accurate sensor available as compared to other sensing technologies
» Latching alarm indicator - remembers which unit initiated an alarm
» Intelligent Sensing TechnologyTM helps reduce the number of nuisance alarms
» Perfect Mount - allows for easy alignment of alarm
» Single button test/silence
» Easy Installation/Maintenance - Preferred features include a large opening in the mounting bracket for easy access to wiring. Keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation. A battery pull tab keeps the battery fresh until the home is occupied. Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the side load battery compartment. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a 'Quick-Connect' wiring harness. Installation is quick, easy and cost effective.
» Dust Cover
» 10-Year Limited Warranty
» Sensor: Ion & Electrochemical
» Warranty Claim: 10-Year
» Package Type: Box
» Color: White
» Battery backup: Y
» Packs per case: 12
» L (inches): 5.69
» W (inches): 2.25
» H (inches): 5.59
» Cube (ft3): 0.041
» Weight (lb): 0.63
First Alert Smoke And Carbon Monoxide Alarm Manual
» Case UPC: 20029054015376» Case Length: 14.43
» Case Width: 6.19
» Case Height: 12.63
» Case Cube (ft3): 0.653
» Case Weight (lb): 8.1
» # of Layers: 3
» # Cases/pallet: 57
First Alert Smoke And Carbon Monoxide Alarm Owners Manual
» # Units/pallet: 684» Pallet Cube (ft3): 42.2
» Pallet Weight (lb): 527
» User Manuals - Spanish Version (Original as in Box)
» Specification Sheets
» High Res Image
Comments are closed.