By Danfoss Danfoss 175R5271 Manual VLT 5000 Series Available from these sellers. View and Download Danfoss VLT 5000 instruction manual online. Modbus RTU, Adjustable Frequency Drive. VLT 5000 Controller pdf manual download. Also for: Vlt 6000 hvac.
The VLT® 5000 is in the Inactive phase and has reached the end of its lifecycle. Danfoss offers an extensive portfolio of low-voltage drives and can help you select the optimal replacement drive for your application. Danfoss’ lifecycle management model recommends replacement using the DrivePro® Retrofit service.
Inactive: A drive in the Inactive phase has no spare parts or service options available. Operating a drive whilst in this phase may result in unpredictable process downtime due to wear or failure. To avoid these risks, we recommend retrofitting with a new-generation replacement drive, to bring the latest technological advantages to your application.
Successor Product VLT® Automation Drive FC 302
The VLT® AutomationDrive FC 302 represents a single drive concept that controls the entire range of operations from ordinary to servo-like applications on any machine or production line. The modular open-technology platform on which the VLT® AutomationDrive is built makes it exceptionally adaptable and easy to program.
Power range
3 x 200-240 V..............0.25-37 kW
3 x 380-500 V...........0.37-1100 kW
3 x 525-600 V..............0.75-75 kW
3 x 525-690 V............1.1-1400 kW
Power range - Low harmonic drive
3 x 380-480 V .............132-710 kW
Power range - 12-pulse drive
3 x 380-500 V........... 250-1000 kW
3 x 525-690 V ...........250-1400 kW
Read more about VLT® AutomationDrive FC 302
Find technical documentation for VLT® 5000
Read more about DrivePro® services
The VLT 5000 has been superceded by the FC301 and FC302
- The VLT® 5000 series suits all industrial applications.
- The compact size saves valuable space.
- The perfect speed matching to actual load reduces your energy costs.
Product range
- 0.75 – 355 kW
- (200 – 240 V, 380 – 500 V and 525 – 600 V)
Easy to commission and use
If you know one drive you also know the others.
A Quick Menu guides you easily through the limited programming work left for you to make the drive perfect for the job in your plant.
SyncPos
To complement the comprehensive functionality of VLT® frequency converters Danfoss Drives offers dedicated engineering solutions for your application.
Based on the high flexibility of the Programmable SyncPos motion controller we tailor solutions to fit perfectly application requirements.
Built-in RFI
Filters available for the entire product range complying with EN55011, class 1A and 1B.
Complies also with IEC 61000-3-2 and 61000-3-4 as well as VDE 0160 as regards levels of harmonic suppression. That reduces the dimensions of cables substantially.
Multi-Setup
The drive has four independent setups.
Click for the Danfoss VLT5000 Brochure.
VLT5000 shown below for all sizes up to 355kW:
VLTtype | Kw – at Motor Shaft CT 160%/FLC (A) | Kw – at Motor Shaft CT/VT 110%/FLC (A) | BOOKSTYLE IP20 | COMPACT IP20 | COMPACT IP54 |
VLT5001 | 0.75kw/2.2A | – | 175Z0034 | 175Z0119 | 175Z0233 |
VLT5002 | 1.1kw/2.8A | – | 175Z0040 | 175Z0125 | 175Z0245 |
VLT5003 | 1.5kw/4.1A | – | 175Z0046 | 175Z0131 | 175Z0257 |
VLT5004 | 2.2kw/5.6A | – | 175Z0052 | 175Z0137 | 175Z0269 |
VLT5005 | 3.0kw/7.2A | – | 175Z0058 | 175Z0143 | 175Z0281 |
VLT5006 | 4.0kw/10.0A | – | 175Z0064 | 175Z0149 | 175Z0293 |
VLT5008 | 5.5kw/13.0A | – | 175Z0070 | 175Z0155 | 175Z0305 |
VLT5011 | 7.5kw/16.0A | – | 175Z0076 | 175Z0161 | 175Z0317 |
VLT5016 | 11kw/24.0A | 15kw/24.0A | – | 175Z4099 | 175Z4105 |
VLT5022 | 15kw/32.0A | 18.5kw/32.0A | – | 175Z4117 | 175Z4123 |
VLT5027 | 18.5kw/37.5A | 22kw/37.5A | – | 175Z4135 | 175Z4141 |
VLT5032 | 22kw/44.0A | 30kw/44.0A | – | 175Z4153 | 175Z4159 |
VLT5042 | 30kw/61.0A | 37kw/61.0A | – | 175Z4171 | 175Z4177 |
VLT5052 | 37kw/73.0A | 45kw/73.0A | – | 175Z4189 | 175Z4195 |
VLTtype | Kw – at Motor Shaft CT 150%/FLC (A) | Kw – at Motor Shaft CT/VT 110%/FLC (A) | COMPACT IP00 | COMPACT IP20 | COMPACT IP54 |
VLT5060 | 45kw/90.0A | 55kw/106.0A | 176F0010 | 176F0022 | 176F0028 |
VLT5075 | 55kw/106.0A | 75kw/147.0A | 176F0040 | 176F0052 | 176F0058 |
VLT5100 | 75kw/147.0A | 90kw/177.0A | 176F0070 | 176F0082 | 176F0088 |
VLT5125 | 90kw/177.0A | 110kw/212.0A | 176F0100 | 176F0112 | 176F0118 |
VLT5150 | 110kw/212.0A | 132kw/260.0A | 176F0130 | 176F0142 | 176F0148 |
VLT5200 | 132kw/260.0A | 160kw/315.0A | 176F0160 | 176F0172 | 176F0178 |
VLT5250 | 160kw/315.0A | 200kw/368.0A | 176F0190 | 176F0202 | 176F0208 |
VLT5300 | 200kw/395.0A | 250kw/480.0A | – | – | – |
VLT5350 | 250kw/480.0A | 315kw/600.0A | – | – | – |
VLT5450 | 315kw/600.0A | 355kw/658.0A | – | – | – |
VLT5500 | 355kw/658.0A | 400kw/745.0A | – | – | – |
- Technical Features
- Integrated RFI filters and DC link chokes.
- RFI filter meets domestic level standard
- Optional cards include fieldbus, Cascade pump control, additional relays etc.
VLT 5000 General Options
Part Number | Description | Used on VLT |
175Z0401 | LCP Keypad / display | All |
175Z0850 | Remote mounting kit for LCP (Includes 3 m cable) | All – (IP.00 & 20) |
175Z7802 | Remote mounting kit for LCP (includes 3 m cable) | All – (IP.54 only) |
175Z0929 | Cable for LCP – 3 metres (also includes in remote kit) | All – (not IP.54) |
Positioning and Synchronising Options | ||
175Z0833 | Synchronising / Positioning Card (programmable) | All |
175Z3029 | Synchronising / Positioning card (coated) (Programmable) | All |
Commissioning help may be needed | ||
175Z3055 | Positioning Controller Card (Pre-Programmed) | All |
175Z3057 | Positioning Controller Card (Conformal Coating) | All |
175Z3053 | Synchronising Controller Card (Pre-programmed) | All |
175Z3056 | Synchronising Controller Card (Conformal Coating) | All |
175Z1929 | Encode signal converter (For 5 Volt TTL Encoders) | All |
Application Options* | ||
175Z2500 | Relay option card | All |
175Z2901 | Relay Option card – coated | All |
175Z3463 | Ring spinning option (not factory mounted) | All |
175Z3245 | Winder option (Not factory mounted) | All |
175Z3467 | Wobble option (not factory mounted) | All |
Fieldbus Options* | ||
175Z0404 | Profibus Card including memory option (DP V0/V1) | All |
175Z2625 | Profibus Card including memory option (Coated DP V0 / V1) | All |
175Z3722 | Profibus Card including memory option (DP V0 / FMS) | All |
175Z3723 | Profibus Card inc. memory option (coated DP V0 / FMS) | All |
175Z3568 | Profibus sub D9 connector (IP00 / IP20 versions) | 5001 – 5102 |
176F1822 | Profibus sub D9 connector (IP00 / IP20 versions) | 5125 – 5250 |
176F1580 | Device net card – including memory option | All |
176F1581 | Device net card – including memory option – coated | All |
176F1500 | Lonworks Card, Free topology – including memory option | All |
176F1503 | Lonworks card, free topology – inc memory and coated | All |
176F1501 | Lonworks card, 78 Kbps – including memory option | All |
176F1504 | Lonworks card, 78KBps – inc memory option (coated) | All |
176F1502 | Lonworks card, 1.25 Mbps – including memory option | All |
176F1505 | Lonworks card, 1.25Mbps – inc memory option (coated) | All |
176F1551 | Modbus Plus – including memory option | Compact |
176F1550 | Modbus Plus – including memory option | Bookstyle |
175Z3122 | Interbus option – including memory option | All |
175Z3191 | Interbus option – including memory option – coated | All |
175Z3362 | Modbus RTU (not factory fitted) | All |
Fieldbus Options for use with Sync / Pos. Option | ||
175Z0402 | Profibus – Excluding memory option (DP V1 / V0) | All |
176F1512 | Lonworks, Free topology – excluding memory option | All |
176F1513 | Lonworks card, 78 Kbps – excluding memory option | All |
176F1514 | Lonworks card, 1.25 Mbps – Excluding memory option | All |
176F1584 | DeviceNet – excluding memory option | All |
176F1558 | Modbus Plus – excluding memory option | Bookstyle |
176F1589 | Modbus Plus – excluding memory option | Compact |
175Z2900 | Interbus Option – excluding memory option | All |
175Z0928 | IP.4X Top cover | 5001 – 5011 |
175Z4622 | IP.20 Terminal cover kit | 5016 – 5032 |
175Z4623 | IP.20 Terminal cover kit | 5042 – 5052 |
176F1800 | IP20 Bottom cover | 5060 – 5100 |
176F1801 | IP20 Bottom cover | 5125 – 5250 |
175H4195 | Nema 12 bonding plate (200-240V versions) | 5001 – 5006 |
175H4195 | Nema 12 bonding plate (380 – 500V versions) | 5001 – 5011 |
Additionally externally mounted reactors / filters | ||
175U0015 | Line reactor (for loadsharing) | 5001 |
175U0017 | Line reactor (for loadsharing) | 5002 |
175U0021 | Line reactor (for loadsharing) | 5003 |
175U0024 | Line reactor (for loadsharing) | 5004 |
175U0025 | Line reactor (for loadsharing) | 5005 |
175U0026 | Line reactor (for loadsharing) | 5006 |
175U0028 | Line reactor (for loadsharing) | 5008 |
175U0029 | Line reactor (for loadsharing) | 5011 |
175U0030 | Line reactor (for loadsharing) | 5016 |
175U0031 | Line reactor (for loadsharing) | 5022 |
175U0032 | Line reactor (for loadsharing) | 5027 |
175U0034 | Line reactor (for loadsharing) | 5032 |
175U0036 | Line reactor (for loadsharing) | 5042 |
175U0047 | Line reactor (for loadsharing) | 5052 |
175U1009 | Line reactor (for loadsharing) | 5062 |
175U0070 | Line reactor (for loadsharing) | 5072 |
175U0071 | Line reactor (for loadsharing) | 5012 |
175Z0825 | LC Module (Bookstyle) | 5001 – 5005 book |
175Z0826 | LC Module (Bookstyle) | 5006 – 5011 book |
175Z0832 | LC Module (Compact IP.20) | 5001- 5011 comp |
175Z4606 | LC Filter – 5016 – 160% | |
175Z4607 | LC Filter – 5016 (110%) / 5022 (160%) | |
175Z4608 | LC Filter – 5022 (110%) / 5027 (160%) | |
175Z4609 | LC Filter – 5027 (110%) / 5032 (160%) | |
175Z4610 | LC Filter – 5032 (110%) / 5042 (160%) | |
175Z4611 | LC Filter – 5042 (110%) / 5052 (160%) | |
175Z4612 | LC Filter – 5052 (110%) | |
175Z4700 | LC Filter – 5062 (160%) | |
175Z4701 | LC Filter – 5062 (110%) / 5072 (160%) | |
175Z4702 | LC Filter – 5072 (110%) / 5102 (160%) | |
175Z4703 | LC Filter – 5102 (110%) / 5125 (160%) | |
175Z4704 | LC Filter – 5125 (110%) / 5150 (160%) | |
175Z4705 | LC Filter – 5150 (110%) / 5200 (160%) | |
175Z4706 | LC Filter – 5200 (110%) / 5250 (160%) | |
175Z4707 | LC Filter – 5250 (110%) / 5300 (160%) | |
175Z3139 | LC Filter – 5300 (110%) / 5350 (160%) | |
175Z3140 | LC Filter – 5350 (110%) / 5450 (160%) | |
175Z3141 | LC Filter – 5450 (110%) / 5500 (160%) | |
175Z3142 | LC Filter – 5500 (110%) |
*Note, if purchased as integral option with VLT – special integral part number applies
VLT 5000 Specifications
User Manual For Iphone
|
Comments are closed.